Robina Town Centre Coles Relocation & Carpark Extension

CommercialInfrastructure
Site

Cnr Christine Ave & Robina Town Centre Drive, Robina, QLD 4226

Specifier

Bornhorst Ward Consulting Engineering

Contractor

JK Civil

Description

The Precast StormFilter vault system treats an approximate site area of 36,000 sqm. The commercial development is predominantly made up of hardstand (road) area therefore the utilisation of EnviroPods as the primary form of pre-treatment was essential to capture key pollutants such as Suspended Solids. The treatment devices satisfy Gold Coast City Council Water Quality Objectives of 80% TSS Reduction, 60% TP Reduction , 45% TN Reduction and 90% Gross Pollutant Reduction. The treatment train is designed to provide optimal performance throughout the entire lifecycle with the contribution of periodic maintenance.

Maintenance

The 96 Cartridge StormFilter system is designed to achieve an annual maintenance frequency with EnviroPods to be serviced every 3-6 months. Periodic inspections and cleans are also scheduled to take p